The phrase “sliding window new build standard” gets typed into a search box by people who want one of three different things, and only one of the three exists.
The first is a standard size: a width and a height that a factory keeps in a range and that a builder can order without asking questions. We have written elsewhere about sliding window dimensions and about metric and imperial size tables, so this piece does not repeat that. The honest answer is that no such size is a standard in any code, and we have already made that argument.
The second is a product standard: the document a window is tested and declared against. That exists, it is real, and it decides what gets tested. It does not decide how big your hole in the wall is.
The third is the one that matters and the one almost nobody writes about: a requirement written about the room, not about the window. These rules are the only things in a new build that actually set the size of the opening, and they are written as fractions of floor area, as fixed clear areas, and as ratios between glass and opening. They never name a window type. They simply describe what has to be true of the hole, and it is left to the person specifying the window to work out which window can satisfy them.
Exactly one of those rules is, literally, a new build standard. England’s Approved Document O on overheating applies to new residential buildings and to nothing else: not to extensions, not to conservatories added afterwards, not to a change of use, not to hotels. It is the only rule in the English-speaking world that tells you, as a number, how much your window has to open. And a two-panel sliding window of the sort every catalogue picture shows cannot satisfy it on paper, at any size, for a reason that has nothing to do with how well it is made.
We build sliding windows. We would rather that sentence came from us than from your assessor in month nine.
| Meaning | Who owns it | Can a factory hand it to you | What it actually decides |
|---|---|---|---|
| A catalogue size, a nominal width and height kept in a range | The factory | Yes | Nothing about compliance. It decides what is cheap and what is quick |
| A product standard, such as a harmonised European standard or a North American fenestration standard | A standards body, plus whoever signs the declaration | Partly, and only for the specimen that was tested | What gets measured, and on which specimen. Not how big your opening is |
| A requirement written about the room: escape, ventilation, overheating | Your authority having jurisdiction, not the factory | No. It belongs to the building, and the factory cannot hold it | The size of the hole in the wall |
Only the third row decides the wall. And a new build is the one project type where the wall is still a decision rather than a fact, which is why this question belongs to new build more than to any other phase of a building’s life.
Here is the set of requirements that actually sizes a window in a new build. What matters is not the values themselves but the column that says what each one is a fraction of, because they are not measuring the same object.
| Requirement | Written as | Source we read it from | What it measures | Can a bigger window solve it |
|---|---|---|---|---|
| Emergency escape and rescue opening | A fixed clear area of 5.7 square feet, with minimum dimensions and a maximum sill height | Published extracts of the International Residential Code reproduced by United States building departments and state labour departments | The hole you get, in the fully open position | Yes, but only by adding width, and only down to a hard floor |
| Natural ventilation, openable area | A minimum openable area of 4 percent of the floor area of the room | The same published code extracts, which also carry the daylight figure | The hole you get, expressed against the room | Yes |
| Daylight, aggregate glazing | A minimum glazing area of 8 percent of the floor area | Same clause, same published extracts | The glass, whether it moves or not | Yes, and fixed glass counts |
| Removal of excess heat, England, new residential buildings only | A minimum free area, as the greater of 9 percent of total floor area or 55 percent of the glazing area, plus a separate bedroom figure | Published summaries of the Approved Document O tables and a Welsh Government frequently-asked-questions page | The hole you get, then discounted by a discharge coefficient | One branch yes, the other branch no, at any size |
Four rules. Three different things being measured. Row one and row two measure the hole, row three measures the glass, row four measures the hole and then discounts it. The window industry prints catalogues in only one of those languages, which is why the mismatch is nearly always discovered late.
Take the two figures that sit in the same published clause: glazing not less than 8 percent of floor area, and openable area not less than 4 percent of the floor area being ventilated. Eight and four. The second is exactly half of the first.
That relationship decides the whole argument, and nobody prints it.
The code is not picking on sliding windows. It simply contains no sentence assigning the work to a particular window, so the whole obligation lands on whichever part of whichever window you chose to make movable. A two-to-one relationship is a gift to any window that opens completely and a tightrope for any window that opens halfway.
The published code extracts are unusually explicit about how the escape opening is measured. The net clear opening must be not less than 5.7 square feet, the net clear height not less than 24 inches, the net clear width not less than 20 inches, and the bottom of the clear opening not more than 44 inches above the floor. Grade floor openings are allowed a smaller figure of 5 square feet. One state labour department fact sheet adds the sentence that matters most: the net clear opening dimensions shall be the result of the normal operation of the opening.
For a two-panel sliding window, normal operation means one sash sliding behind the other. The clear width you get is roughly half the frame width. Five point seven square feet is 821 square inches. Our arithmetic, with the assumption stated: net clear width equals one half of the nominal frame width, and net clear height equals the sash height. We have ignored the interlock and frame deductions, which makes every real number worse than the one in this table.
| Net clear height, inches | Minimum nominal frame width, inches | Which rule is doing the work |
|---|---|---|
| 24 | 68.4 | The 5.7 square foot area |
| 30 | 54.7 | The 5.7 square foot area |
| 36 | 45.6 | The 5.7 square foot area |
| 41 | 40.1 | Both, at the same time |
| 48 | 40.0 | The 20 inch minimum width |
| 60 | 40.0 | The 20 inch minimum width |
Two conclusions come out of that table, and we have not seen either of them written anywhere.
First: no two-panel sliding window narrower than about forty inches can be an escape window at any height. The 20 inch minimum width is a floor that you cannot buy your way out of with height, because height does nothing to the width of the moving sash.
Second: there is a height at which the arithmetic changes hands. Divide 821 square inches by the 20 inch minimum and you get 41.05 inches. Below about forty-one inches of net clear height, the area rule is what binds you. Above it, the 20 inch minimum width takes over, and from there you can make the window as tall as you like without moving the required width by one inch.
If you want the same comparison without our arithmetic in it, one North American installer publishes both numbers for the same frame. A 36 by 48 inch casement frame, they say, produces roughly 30 by 44 inches of clear opening, about 0.85 square metres. A 36 by 48 inch slider frame produces roughly 17 by 44 inches, about 0.48 square metres. Same hole in the wall, roughly one and eight tenths times the escape route. That ratio is the whole argument in a single row, and it is not a statement about who built the window.
One of these requirements is a fixed area. The other is a fraction of the room. That difference means one of them is always bigger than the other, and which one it is depends only on the floor area of the room.
Our arithmetic: set 4 percent of the floor area equal to 5.7 square feet, and the crossover sits at 142.5 square feet of floor.
| Room floor area, square feet | The escape number asks for | The ventilation number asks for | Whichever is bigger sets the window |
|---|---|---|---|
| 100 | 5.7 square feet | 4.0 square feet | Escape |
| 142.5 | 5.7 square feet | 5.7 square feet | Either, they are equal |
| 200 | 5.7 square feet | 8.0 square feet | Ventilation |
| 300 | 5.7 square feet | 12.0 square feet | Ventilation, by a wide margin |
Now the part that is genuinely useful. This crossover does not move when you change the window type. Both requirements scale with the same open fraction, so whichever window you pick, the ventilation number overtakes the escape number at the same floor area. The choice between a casement and a slider never decides which rule governs; your architect decided that when they fixed the room size.
Which means the usual order of decision is backwards. Choose the window after you know which rule is binding, not before. In a bedroom smaller than about 143 square feet you are sizing for the fire code, and no ventilation argument moves the number. Above it you are sizing for air, and the escape window is the one that gets met on the way past.
Approved Document O on overheating came into force in England in June two thousand and twenty two according to the published summaries we read. It applies to new residential buildings: houses, flats, care homes, student halls and their shared spaces. Published guidance is explicit that it does not apply to extensions, to conservatories added afterwards, to a change of use, or to hotels.
So this is the one place where the words in our title mean anything at all. It asks two things. Limit unwanted solar gain, which it does by capping glazing area as a percentage of floor area, by orientation, by location and by whether the dwelling can be cross-ventilated. And provide an adequate means of removing heat, which it does by requiring a minimum free area of openable window.
Free area is not the hole. A Welsh Government frequently-asked-questions page on the Welsh edition of the same document defines it: free area will typically be the geometric open area provided by an open window, with fully open windows typically having a coefficient of discharge of 0.62, and it notes that other opening types with a much lower coefficient need proportionally more geometric open area to deliver the same free area. That is the sentence that turns this from a size question into a ratio question.
Our arithmetic, from that published coefficient. Free area is roughly 0.62 multiplied by the geometric open area. The geometric open area of a window is its glazing multiplied by the fraction that actually moves.
| Window | Fraction of the glazing that moves | Multiplied by the published 0.62 | Free area delivered per unit of glazing |
|---|---|---|---|
| Fully openable sash, such as a casement or an inward opener | 1.00 | 0.62 | 0.62 |
| Two-panel slider, one fixed plus one movable | 0.50 | 0.62 | 0.31 |
| Three-panel slider, middle fixed with two moving | 0.67 | 0.62 | 0.41 |
The first branch of the requirement, for a cross-ventilated dwelling outside the London high risk list, is a minimum free area of 9 percent of the total floor area. Divide 9 by each conversion factor above and you get the glazing each window type needs in order to deliver it.
| Window | Glazing needed to deliver 9 percent free area, as a share of floor area | Against the glazing caps in the same tables, 11 to 18 percent |
|---|---|---|
| Fully openable | 14.5 percent | Fits three of the four orientation caps, fails the west-facing one |
| Three-panel slider, two moving | 21.8 percent | Above every cap |
| Two-panel slider, one moving | 29.0 percent | Above every cap, by a wide margin |
A note we insist on, because it is the difference between an argument and a claim. This row mixes a dwelling-wide floor area with a per-façade glazing cap, and the real assessment is done per orientation and per room. It is a screening arithmetic, not a compliance calculation. What it tells you is which questions to ask before the elevations are frozen, and it tells you that loudly enough.
The requirement is written as the greater of two things. The second thing is 55 percent of the glazing area. That is not an area test. It is a ratio test, and a ratio test does not get easier when you make the window bigger, because both sides of it scale together.
A fully openable window converts glazing to free area at 0.62, which is above 0.55, so it passes this branch at any size. A two-panel slider converts at 0.31. A three-panel slider with two moving panels converts at 0.41. Both are below 0.55, and adding glass moves the requirement up at exactly the rate it moves your supply up.
Run it backwards and you get the most useful single number on this page. Divide 0.55 by the published 0.62 and you get 0.887. To pass this branch with a discharge coefficient of 0.62, the share of your glazing that has to open is about 89 percent. A two-panel slider opens about half. A three-panel slider with two moving panels opens about two thirds. Neither is close, and no quantity of either one gets closer.
This is the one requirement in this article that you cannot solve by buying a larger window. It is also, so far as we can tell, the one requirement that nobody in the window industry has written down, because the industry sells area and this rule is not about area.
The same published tables give bedrooms their own figure, and it is an area test rather than a ratio test: 4 percent of the room’s floor area in the moderate risk list, and 13 percent of the room’s floor area in the high risk London list.
Area tests can be solved with size. Our arithmetic: a two-panel slider delivering 0.31 of its glazing as free area needs glazing of about 12.9 percent of the bedroom’s floor area to meet the 4 percent figure. That is a window a real bedroom can hold. In the London list the same arithmetic asks for glazing of about 41.9 percent of the room’s floor area, which sits above the 37 percent cap the same tables place on the most heavily glazed room.
So the same window type, under the same document, passes in one part of England and cannot pass in another. If that sounds like a reason not to generalise, it is.
There is a moment in English residential design where two Approved Documents arrive at the same number from opposite directions, and it is worth seeing because nothing else in this article is so finely balanced.
One document says the opening must be no higher than 1100 millimetres. The other says the guarding must be no lower than it. They meet at a single point, and the official guidance that reconciles them allows the number to move by one hundred millimetres in one direction only: downwards.
For a sliding window this is an instruction rather than a fact of life. The sill height, the guarding and any restrictor are one decision taken on one drawing, and in a new build that drawing still exists. Take it after the frame is ordered and you are choosing between a guarding detail that was never in the elevation and an opening that is no longer where the calculation put it.
The National Construction Code requires a ventilating area of not less than 5 percent of the floor area of the room. So far, so similar. Then the published explanatory information on the code’s own website says something that appears in no other system we have read:
An advisory note published by the same board on protecting openable windows goes further still. Asked whether a device that restricts a window to 125 millimetres affects natural ventilation compliance, it answers no: the window is not required to be always fully open, only capable of being opened, so the ventilating area is still measured as the size of the sash.
Read that against the North American rule, which takes the dimensions that result from the normal operation of the opening, and you get this: the same physical window, in the same wall, is credited at about half in one system and at the whole of its moving sash in the other, and a restrictor that stops it at 125 millimetres costs you nothing in one and everything in the other.
Neither is a mistake. One is measuring the hole you get. The other is measuring the thing that moves. The word being defined twice is “openable”. Which is why the practical rule is not “remember the number” but “carry the definition with the number”. A ventilation compliance calculation done under one definition cannot be re-read under the other, and it will not announce that it has changed.
Published Canadian guidance gives an egress opening of 0.35 square metres with no dimension less than 380 millimetres. One contractor’s published guide offers a rule of thumb for a casement: take the nominal width and height, subtract 50 millimetres from each dimension, and multiply, treating the result as a planning estimate only and never as a substitute for measuring. For a horizontal slider the same source says the window opens to only half its nominal width and offers the worked example of a 36 by 24 inch slider delivering only about 0.23 square metres, below the 0.35 minimum.
The interesting part is the restrictor. Window opening control devices to the ASTM F2090 standard typically limit a window to 100 millimetres. Published Alberta guidance says these are permitted on egress windows provided the device releases easily in an emergency without keys, tools or special knowledge — and it notes, explicitly, that this is a meaningful provincial distinction, because the national base code did not permit them on egress windows at all.
The device that stops a child falling out is the same device that closes your escape route, and two Canadian code bodies have answered that question in opposite directions. If your project sits anywhere near a jurisdictional boundary, ask which answer applies before you specify the hardware. Hardware is the one item on a window order that is frequently non-returnable, because it cannot be resold as a different configuration.
Everything above is unfavourable to a slider on paper. Here is the case that is actually in its favour, and it has nothing to do with area.
A casement that opens outward puts its sash outside the wall. One Toronto installer publishes the number: a 36 inch casement opens to project about 30 inches into the window well. Meanwhile the published code extracts require an area well of not less than 9 square feet with a horizontal projection and width of not less than 36 inches, require the well to allow the opening to be fully opened, require any required ladder not to be obstructed by the opening in the open position, and require openings under decks and porches to be fully openable with a path of not less than 36 inches to a yard or court.
The well was dimensioned for a person, and the open sash is now sharing it with the person. That is a real constraint in a below-grade bedroom, and it is why installers who do this work every week put casements on most of those jobs. It is also exactly why the sliding window still has work to do: it opens nothing into the space outside the wall.
The rest of the case lives on the site plan rather than in the window schedule. A boundary. A public walkway. A narrow balcony. A pool fence line. A party wall. An elevation where a row of open casements is not the facade the architect drew. None of those are window arguments, and all of them are settled while the site is still a drawing, which is another way of saying they are new build arguments.
And there is one more that belongs to new build alone. In a new build the wall is a decision, so the penalty for a half-opening window is paid in wall. If you have the wall, the penalty is cheap, and a slider that fails every ratio test above can still be the right window for a room that is not the escape route and not the ventilation path. If you do not have the wall, no amount of better hardware repairs it.
Our sliding window range holds one product. Its two published configurations are one fixed plus one movable, and a middle fixed panel with a moving panel either side. Those are open fractions of one half and two thirds.
Against the roughly 89 percent that the English ratio test implies, neither of them is a candidate. We would rather you heard that here than from your assessor after the elevations are frozen. If your project is an English new build assessed under the simplified method, the sliding window is not the thing that discharges that requirement, and the honest alternatives are a fully openable sash where the elevation allows it, a route through dynamic modelling, or making the free area up with openings that are not windows.
| What we publish | What it is | What it is not |
|---|---|---|
| Frame wall width 130 millimetres | The depth the frame occupies in the wall | Not the width you see, and not the opening. It is the number your wall build-up has to accommodate |
| Glass sash thickness 55 millimetres | A stack-up of the sash | Not the glass, and not the rebate. The ceiling on glass thickness is on the section drawing, not in a specification table |
| Sash width 75 millimetres | The visible sash member | It is part of the half you do not get as opening, and every millimetre of it comes out of the net clear width |
| Frame width 26 millimetres | A sightline, and the number that gets quoted in marketing | It says nothing about any of the four requirements in this article |
| Track height 53 and 31 millimetres | Two tracks, and they are different | The lower one is the bottom of your opening. It is also the height your sill measurement starts from |
| Load-bearing pulleys rated at 200 kilograms | A rated value for one sash | Not a maximum panel size. Any maximum is published against an assumed glass build, so changing the glass changes it. Ask for the number against yours |
| Eight-point locking | The mechanism that pulls the sash across to compress the seal | It is a sealing device at least as much as a security one. An unadjusted one is a six-point lock doing eight points of work |
| A 240 hour salt spray result and a 5,000 newton shear value elsewhere in our catalogue | Published test results on a particular series, measuring coating and substrate, and the composite bond between insulation strip and aluminium | Neither is an air, water or wind rating, neither is any of the four numbers above, and neither transfers to the sliding window |
Our published specification for the sliding window does not include air permeability, water tightness or wind resistance classes. We would rather say that plainly than let you build a schedule on a gap. Not published does not mean worse; it means there is nothing to compare. Ask for a calculated value for your opening, your glass build and a named standard, and ask for it before the elevations are frozen.
The reason this is a new build subject at all is timing. Every one of these requirements is free at one stage and expensive at the next.
| Stage | What gets frozen | Who freezes it | What a late change costs |
|---|---|---|---|
| Room layouts and floor areas fixed | Every percentage in this article becomes a fixed quantity | Architect | Everything downstream. This is the stage where the crossover between the escape rule and the ventilation rule is decided, and nobody notices |
| Escape strategy agreed | Which opening is the escape route, and whether it is a window or a door | Designer with the authority | An opening, a lintel, sometimes a stair |
| Elevations and glass areas set | The glazing caps, and therefore the overheating branch | Architect | The ratio branch cannot be recovered by adding glass, so this stage can remove a route permanently |
| Opening types selected | The open fraction, which is every row of the conversion table | Specifier | A reassessment, or a change of route to dynamic modelling |
| Profiles cut | Lengths, colour batch, hardware set | The order | Scrap and a second production slot |
| Installed | The hole, and the inspection that reads it | The site | Remedial works, and a compliance conversation that no longer has a cheap answer |
Only the first four rows are free, and only in a new build are the first four still free. That is the whole argument for asking these questions now.
| Item | Our position | Why the gap exists | What to do |
|---|---|---|---|
| Net clear opening dimension of a named configuration | Not published as a schedule | It depends on the frame width, the interlock and how far the sash travels, and it is not the nominal size | Ask for the clear opening in millimetres for the exact configuration you are buying |
| Open fraction of the configuration | Derivable from the two published configurations | We publish the arrangement, not the resulting fraction | State the fraction you need in the enquiry and make the supplier confirm it in writing |
| Air permeability, water tightness, wind resistance classes on the sliding window | Not in our published material | They belong to a tested specimen, and we have not published one for this range | Ask for a calculated value under a named standard, and ask which specimen it was measured on |
| Thermal value | Published for a different series, and it is a system value | A system value is not a whole-window value and not the rating your authority asks for | Ask for the value for your size, your glass build and your standard |
| Maximum panel size | Published against an assumed glass build | Glass dominates sash weight, so the number is a function of your glass, not of the profile | Never order size and glass separately. Send them as one line |
| Escape approval for your project | We cannot hold it | Approval attaches to the building and to the authority, not to a product or a factory | Ask your designer to name the escape opening on the plan before the frame is ordered |
| Overheating compliance for your dwelling | We cannot hold it | It is a whole-dwelling calculation with orientation, shading and ventilation in it | Give your assessor the open fraction and the free area, not the frame size |
| The opening in the wall, and how it is sealed | Not ours | The perimeter seal belongs to the building envelope, not to the window | Name who signs it, in writing, before installation |
Copy this block, fill it in, and send it with the drawing. The third column is the one that matters: it is what happens when a line is left empty.
| Line | Fill in | If it is blank |
|---|---|---|
| 1. Authority and edition | Name the code, the edition and any local amendment | Every number below is quoted against a default, and the default is probably not yours |
| 2. Which requirement governs this opening | Escape, ventilation, overheating, or daylight | The supplier will size it for the cheapest of the four |
| 3. Room floor area served | In square metres and square feet, one or the other is wrong on site | The percentages cannot be turned into quantities |
| 4. Required opening, in the unit your authority uses | Square feet, square metres, or a percent of floor area | Someone will convert it, and the conversion will be a different measurement |
| 5. Configuration and open fraction | How many panels, how many move, and the fraction that results | The whole conversion table above becomes a guess |
| 6. Required net clear opening, millimetres, width by height | Measured, not nominal | The frame will be sized to a catalogue number that is not the opening |
| 7. Sill height and finished floor level | Both, in millimetres, from the same datum | The escape opening can end up above the height the rule allows |
| 8. Restrictor or opening control device, yes or no | State the standard it is tested to and whether it releases without a tool | A fall-prevention device quietly becomes an escape obstruction, and jurisdictions disagree about it |
| 9. Glass build, full specification | Thickness, cavity, coating, gas | Sash weight is unknown, so every rated value and maximum size is unknown |
| 10. Wall build-up, outside to inside, in millimetres | Every layer, not one total depth | A frame depth is matched to a wall depth that does not exist on site |
| 11. Anything outside the wall that the sash would hit | Boundary, walkway, balcony, well, deck, external unit | The argument for a sliding window is made after the one for an opener is lost |
| 12. Who signs the perimeter seal | A named trade, on the programme | The one seal nobody wants turns into a defect nobody owns |
| Ask | A real answer contains | Sounds reasonable, carries no information |
|---|---|---|
| What is the net clear opening | Two numbers in millimetres, for this configuration | “It is a standard size” |
| What fraction of the glazing opens | A fraction, stated, with the panel arrangement | “It opens fully” |
| Which standard is the rating against | A standard number and a year | “It meets international standards” |
| Which specimen was tested | A size, a configuration and a glass build | “The series is tested” |
| What is the maximum panel | A size, with the glass build it assumes | “Up to three metres” |
| What is the pulley rating | A value per sash, and the wheel count | “Heavy duty” |
| Is a restrictor fitted, and to what standard | A standard number, and whether it releases without a tool | “Child safe as standard” |
| What is the glass rebate | A dimension from the section drawing | “It takes all standard glass” |
| Who signs the perimeter seal | A trade, named, on the programme | “The installer handles that” |
| Can you hold my project approval | No, and an explanation of what can be supplied instead | Any version of yes |
A new build is not one window order. It is several, bought by different people at different times, and only one of them is ours. The external envelope is the one we can quote. The internal joinery package — room dividers, wardrobe fronts, shower screens, things sold as vinyl folding doors — is not something we produce, and we will say so rather than substitute a sliding door for it. The ironmongery and finishing package, including handles, closers, screens and shading, is usually bought last and is the one most often missing from the programme.
The same caution applies to doors in a wall that carries an escape requirement. Nominal door names are not leaf sizes and not opening sizes, and a page describing a 34 inch entry door is describing a catalogue call-out, not a dimension you can put on a drawing. We have worked on villa projects in Saudi Arabia, Dubai and Australia, and the one thing every one of them had in common is that the openings were settled on a drawing long before anyone discussed glass.
Not in any code. There are common catalogue sizes, and there are the ranges individual factories hold, and we have written about those elsewhere. What no code does is name a size for a sliding window. It names outcomes — a clear opening, a fraction of a floor area, a ratio between glass and opening — and leaves the size to be derived. That derivation is the whole of this article.
Yes, and it is done constantly, but it costs wall. Because the moving sash stops behind the fixed one, a two-panel slider needs a frame roughly twice as wide as a fully openable window would for the same clear opening, and it can never be narrower than about forty inches regardless of how tall it is. One published comparison of the same 36 by 48 inch frame gives about 0.85 square metres of clear opening for a casement and about 0.48 for a slider.
It cannot meet one particular branch of one particular method, and the honest version is narrower than the headline. The glazing-ratio branch of the simplified method asks for free area equal to 55 percent of the glazing area. A window with a discharge coefficient of 0.62 needs about 89 percent of its glazing to open in order to deliver that. A two-panel slider opens about half. The dwelling-wide area branch and the bedroom branch are different tests and are solvable with size. The other routes — dynamic modelling, mechanical cooling, non-window openings — are all legitimate and all used.
Because they define the thing being measured differently. A published North American clause asks for openable area as a share of floor area, and the dimensions are those that result from normal operation of the opening. The English overheating tables ask for free area, which a Welsh Government page describes as the geometric open area discounted by a coefficient of discharge of about 0.62 for a fully open window. The Australian code’s own explanatory information says the ventilating area is measured as the size of the openable sash, regardless of type and irrespective of restrictions on the sash. Three definitions, and the same window scores differently in each.
It depends entirely on where you are, and this is not a question to generalise about. Published Alberta guidance says compliant opening control devices are permitted on egress windows provided they release without a key, tool or special knowledge, and notes that this is a provincial distinction because the national base code did not permit them. The Australian board’s advisory note takes a different view of the same class of device for ventilation purposes, on the grounds that the sash remains capable of being opened. Ask your authority, and ask before the hardware is ordered, because handed and configured hardware is frequently non-returnable.
The twelve-line block above, filled in. Two lines do the most work: the required opening in the unit your authority uses, and the open fraction you need. Those two together tell us whether a sliding window is even the right starting point, and we would rather tell you it is not in the first week than quote you a frame that cannot pass.